HVAC 1330 Commercial Refrigeration Installation
2.0 - 3.0 - 3.0
Prerequisite
(3)
HVAC 1000;
HVAC 1010; and
HVAC 1020Course Description
Students install a complete refrigeration system (low-temperature/medium-temperature) using hard-drawn copper tubing. Students also wire, leak check, evacuate, and charge the unit using the correct refrigerant. Upon completion of this unit, the refrigerator must run, cool, and defrost according to manufacturer's specifications.